    Electric gate valve Z962Y-P54

    Update: 2016/5/30??????View:
    • name: ???Electric gate valve Z962Y-P54
    • Type: ???Z962
    • Presure: ???P54 100V、P54 140V、P54 170V
    • Specifications: ???DN50~DN350
    • material: ???12Cr5MoV
    • Order Online

    • The product description

      Special high temperature and high pressure power station gate "also known as power station valve, the pipeline is mainly used in the thermal power plant all kinds of system, cut off or connect pipe medium. Applicable medium: water, steam and other corrosive medium. Power station valve compared with other valve products is characterized by high temperature and high pressure, the unique since the seal design, the higher the pressure, the more reliable seal. Because of performance technology characteristics, operating mode of the special products have formed the characteristics do not replace the other products. This kind of valve shall generally be installed in the pipeline.




    • The main dimensions and weight 1500Lb

      Nominal diameter

      Main shapes and connection size(mm)

      Electric actuator

      d

      L

      H

      H0

      L1

      L2

      2-1/2"

      56

      254

      520

      200

      140

      243

      SMC-04

      3"

      64

      305

      523

      200

      140

      243

      SMC-04

      4"

      85

      406

      599

      508

      198

      281

      SMC-03

      599

      305

      400

      555

      SMC-00

      5"

      100

      483

      678

      508

      198

      281

      SMC-03

      678

      305

      400

      555

      SMC-00

      6"

      126

      559

      793

      305

      410

      565

      SMC-0

      793

      305

      420

      654

      SMC-1

      8"

      158

      711

      813

      305

      410

      565

      SMC-0

      813

      305

      420

      654

      SMC-1

      10"

      200

      864

      998

      457

      440

      688

      SMC-2

      988

      305

      420

      654

      SMC-1

      12"

      250

      991

      1141

      305

      420

      654

      SMC-1

      1156

      457

      440

      688

      SMC-2

       The main dimensions and weight 2000Lb

      Nominal diameter

      Main shapes and connection size(mm)

      Electric actuator

      d

      L

      H

      H0

      L1

      L2

      2-1/2"

      50

      330

      540

      200

      140

      243

      SMC-04

      3"

      60

      368

      558

      508

      198

      332

      SMC-03

      4"

      80

      457

      654

      305

      400

      555

      SMC-00

      5"

      96

      533

      780

      305

      400

      555

      SMC-00

      780

      305

      410

      565

      SMC-0

      6"

      118

      610

      830

      305

      410

      565

      SMC-0

      8"

      148

      762

      960

      305

      410

      565

      SMC-0

      960

      305

      420

      654

      SMC-1

      10"

      180

      914

      1020

      304

      420

      654

      SMC-1

      1024

      457

      440

      688

      SMC-2

      12"

      222

      1041

      1150

      457

      440

      688

      SMC-2

      14"

      254

      1118

      1230

      457

      440

      688

      SMC-2

       The main dimensions and weight 2500Lb

      Nominal diameter

      Main shapes and connection size(mm)

      Electric actuator

      d

      L

      H

      H0

      L1

      L2

      2-1/2"

      46

      330

      533

      508

      198

      332

      SMC-03

      533

      200

      140

      243

      SMC-04

      3"

      54

      368

      549

      508

      198

      332

      SMC-03

      549

      200

      140

      243

      SMC-04

      4"

      70

      457

      653

      508

      198

      332

      SMC-03

      644

      305

      410

      565

      SMC-0

      5"

      86

      533

      760

      305

      400

      555

      SMC-00

      774

      305

      400

      565

      SMC-0

      6"

      104

      610

      850

      305

      400

      555

      SMC-00

      861

      305

      410

      565

      SMC-0

      8"

      130

      762

      847

      305

      410

      565

      SMC-0

      860

      305

      420

      654

      SMC-1

      10"

      162

      914

      1021

      305

      420

      654

      SMC-1

      The main dimensions and weight 3500Lb

      Nominal diameter

      Main shapes and connection size(mm)

      Electric actuator

      d

      L

      H

      H0

      L1

      L2

      3"

      44

      440

      620

      508

      198

      332

      SMC-03

      623

      305

      400

      555

      SMC-00

      4"

      56

      540

      721

      305

      400

      555

      SMC-00

      730

      305

      410

      565

      SMC-0

      5"

      74

      616

      796

      305

      410

      565

      SMC-0

      796

      305

      420

      654

      SMC-1

      6"

      88

      692

      857

      305

      410

      565

      SMC-0

      857

      305

      420

      654

      SMC-1

      8"

      116

      846

      1041

      305

      420

      654

      SMC-1

      1051

      457

      440

      688

      SMC-2

      10"

      142

      1000

      1197

      457

      440

      688

      SMC-2


    • The major parts material


      Valve body, valve cover, gate

      The stem

      Stem and nut

      filler

      handwheel

           C

      ASTM A216 WCB carbon steel

       20Cr13

      ZQAL9-4

      graphite

      malleable iron

           P

      ASTM A351 CF8(304) stainless steel

       ASTM A182 F304

      ZQAL9-4

      PTFE

      malleable iron

           R

      ASTM A351 CF8M(316) stainless steel

       ASTM A182 F316

      ZQAL9-4

      PTFE

      malleable iron

           I

      ASTM A217 WC6 Cr Mo steel

       38CrMoAL

      ZQAL9-4

      graphite

      malleable iron

           V

      ASTM A217 WC9 Cr Mo steel

       25Cr2MoVA

      ZQAL9-4

      graphite

      malleable iron

      Other special materials, our company can also be tailored to customer needs.

    • The performance specification

      shell material

      applicable medium

      applicable temperature(℃)

      Carbon steelC type

      Water, steam, oil

      425

      Chromium nickel titanium steelP type

      Nitrate class

      200

      Titanium nickel chrome molybdenum steelR type

      Acetic acid class

      200

      Chrome molybdenum steelI、V type

      Water, steam, oil

      550

      Nominal pressureLb

      shellMPa

      Test pressureMPa

      upper sealMPa

      seal(liquid)MPa

      seal(gas)MPa

      1500

      37.5

      27.5

      0.6

      27.5

      2000

      54

      39.6

      0.6

      39.6

      2500

      63

      46.2

      0.6

      46.2

    • Implementation standards:
      Design standard: B16.34 API ASME 600 E101
      Structure length: B16.10 E101 ASME
      Groove size: ASME B16.25
      Experiment and test: API 598
      Pressure - temperature: B16.34 ASME
      Product label: B16.34 ASME
    • Storage and maintenance
      Valves can be stored in any area of the mask, but must pay attention to prevent the valve is soil or ground dirty. At the time of shipment, the inlet and outlet of the valve are provided with a protective cover. Note that before the installation of the valve, do not remove these protective cover. When the valve is ready to be installed, the protective end cover is removed first, and then the connection parts are cleaned. If is the butt welding end of the valve, to remove all visible foreign body. Use suitable solution to clean the parts that need to be welded, such as acetone or alcohol. Do not use a solution containing fluoride or chloride.
      Installation and maintenance
      1 handwheel, handle and drive mechanism for lifting are not allowed to use, and avoid collision.
      2 double gate valve should be installed vertically (that is, the valve stem is in the vertical position, the hand wheel at the top).
      3 valve with bypass valve should be opened before opening the bypass valve (in order to balance the pressure of the inlet and outlet and reduce the opening force).
      4 with the transmission mechanism of the gate valve, according to the provisions of the product manual installation.
      5 if the valve is often used to switch, at least once a month.